Carey Foster Bridge

Carey Foster Bridge

Howdy Friends, this post gives data about the Carey Foster bridge. We will likewise figure out how this bridge can be utilized to decide the opposition in detail by inferring an articulation for deciding obstruction.


Carey-Foster bridge Experiment

We have just observed some essential strategies for estimating medium protections. Carey foster bridge is the strategy utilized for the estimation of medium opposition. Carey foster bridge is exceptionally utilized for the correlation of two equivalent protections. The circuit for Carey-Foster Bridge appears in the figure beneath. A slide wire having length L is incorporated among R and S. opposition P and Q are balanced with the goal that the proportion P/Q is around equivalent to R/S. this can be accomplished by sliding contact on slide wire.


Carey Foster Bridge Working Principle

The working guideline of the Carey Foster bridge is like the Wheatstone bridge. The potential fall is specifically relative to the length of the wire. This potential fall is almost equivalent to the potential fall over the obstruction associated in parallel to the battery.


Depiction

Let l1 be the separation of the sliding contact from the left-hand end of the slide-wire of Carey foster bridge. The opposition R and S are exchanged and balance is again acquired. Let the separation is currently l2.

Let r= resistance/unit length of slide wire

For the first balance,

Carey foster bridge method 1

For the second balance,

Carey foster bridge method 2

Comparing,

Carey foster bridge

Where l1 and l2 have adjusted focuses when the slide wire is aligned by shunting S with a known opposition and S' is the estimation of S when it is shunted by a known obstruction. In this way, the Carey foster bridge can be utilized to quantify the medium opposition.


Some Importance Question-answer About Carey Foster Bridge


Q. What is obstruction?

A. Resistance R=V \ I, where V is the potential contrast connected over the wire and I is the present coursing through it because of the potential distinction.


Q.What is explicit opposition?

A. The particular opposition of a material is the obstruction of the one-centimeter length of wire whose cross-sectional region is one square centimeter.


Q. What is the impact of temperature on the opposition?

A. Opposition increments with increment in temperature of the material of the wire.


Q.In what materials the opposition diminishes with increment in temperature?

A.In Semiconductors


Q. In the event that the span of wire is multiplied will the particular opposition change?

A. Explicit obstruction is free of length or range of wire it just relies upon the material of the wire.


Q.Why is the obstruction wire multiplied before twisting over the bobbin?

A. To stay away from the inductive impacts. The course of current in one wire is inverse to the next consequently the all-out transition is constantly zero.


Q.What is the standard of Carey Foster Bridge?

A. The situation of invalid point changes on the wire when the opposition is associated with the external holes is traded. The distinction in the estimation of opposition is equivalent to the obstruction of the contrasts between bridge wire i.e (L-l).


Q.What is the standard of Wheatstone Bridge?

A. At the point when the four protections P, Q, R, S in the four arms of the Wheatstone bridge are to such an extent that there is no redirection in the galvanometer, we have

P/Q=R/S


Q.When is Carey Foster Bridge generally touchy?

A. It is most touchy when P, Q, R, S are the equivalent or of a similar request.


Q.Why the obstruction for inward proportion arms be equivalent?

A.For expanded affectability and precision.


Q.What is the base contrast in protections that can be estimated via Carey Foster Bridge?

A.The obstruction of the one-millimeter length of the bridge wire.


Popular posts from this blog

Limitations of Terzaghi Theory

Limitations of Terzaghi Theory The value of the coefficient of consolidation has been assumed to be constant.  The distance d of the drainage path cannot be measured accurately in the field. The thickness of the deposit is generally variable, and an average value has to be estimated.  There is sometimes difficulty 1n locating the drainage face, sometimes thin previous seams that can act as good drainage face are missed in the boring operations. The equation is based on the assumption that the consolidation is one-dimensional. In the field, the consolidation is generally 3-dimensional. The lateral drainage may have a significant effect on the time rate of consolidation. The initial consolidation and secondary consolidation have been neglected. Sometimes these form an important part of the total consolidation. In actual practice, the pressure distribution may be far from linear or uniform. Read More Muller-Breslau principle

Price Guard Wire Method

Price Guard Wire Method Some form of  Price Guard Wire Method  is generally used to eliminate the errors caused by leakage currents over insulation. Fig. 3.14 illustrates the operation of This Method. In fig 3.14(a), a high resistance mounted on a piece of insulating material is measured by the ammeter voltmeter method. The micro-ammeter measures the sum of the current through the resistor (IR) and the current through the leakage path around the resistor. The measured value of resistance computed from the readings indicated on the voltmeter and the microammeter, will not be a true value but will be in error.   Figure 3.14 Application of  guard  circuit for measurement of high resistance In fig, 3.14 (b), the  guard  terminal has been added to the resistance terminal block. The  guard  terminal surrounds the resistance terminal entirely and is connected to the battery side of the micro-ammeter. The leakage current IL now bypasses t

Negative Booster

Negative booster A negative booster is employed to conform to the regulation that the potential difference between any two points of the rail return shall not exceed 7 V. Two boosters, positive and negative, are used which are mechanically coupled together and driven by a DC motor. The positive booster is connected to the trolley wire (near the generating station) and the negative booster (separately excited) is connected to the track rail.  The 'positive booster' adds voltage to the line while the 'negative booster lowers the potential of the point it is connected to. As we go along the trolley wire away from the generating station/sub-station, the potential drop increases, and the voltage of the trolley wire falls. Since the current returns via the track rail points away from the generating station acquire high potentials. This potential is brought down by the negative boost provided by the negative booster. When the load is sufficiently far away from the generating stati