Septic Tank Is

Septic Tank Is

In normal areas and in the case of isolated buildings and institutions, hotels, hospitals schools, small residential colonies, an underground sewerage system with provision for complete treatment of sewage may be neither feasible nor economical even though water supply facilities exist. In such cases, septic tanks and subsurface disposal of effluent are provided.

Septic Tank Is



The septic tank is should be located as far as possible away from buildings. It should not be located in swampy areas or areas prone to flooding. Where there are 15 clayey or nonporous soil or where houses are closely built suitably designed loading pits may have to be used a septic tank is cannot be avoided. Where the soil IS heavily porous the septic tank is effective.

The septic tank 15 a water-tight, single-storeyed, underground tank 111 which sewage is retained for a long period. Here sedimentation and sludge digestion take place simultaneously. The Septic tank is generally rectangular in shape with R.C.C. roofing.

 Usually, it has two chambers separated by a baffle wall. Sewage enters the front chamber known as the grit or screen chamber. The other is the anaerobic chamber. The Septic tank should be properly ventilated with the provision of air vent pipes. A manhole is provided in the roof for inspection and cleaning: Sludge accumulated at the bottom of the Septic tank is removed at intervals either by manual labor or by pumping.


Read More

Popular posts from this blog

Limitations of Terzaghi Theory

Limitations of Terzaghi Theory The value of the coefficient of consolidation has been assumed to be constant.  The distance d of the drainage path cannot be measured accurately in the field. The thickness of the deposit is generally variable, and an average value has to be estimated.  There is sometimes difficulty 1n locating the drainage face, sometimes thin previous seams that can act as good drainage face are missed in the boring operations. The equation is based on the assumption that the consolidation is one-dimensional. In the field, the consolidation is generally 3-dimensional. The lateral drainage may have a significant effect on the time rate of consolidation. The initial consolidation and secondary consolidation have been neglected. Sometimes these form an important part of the total consolidation. In actual practice, the pressure distribution may be far from linear or uniform. Read More Muller-Breslau principle

Price Guard Wire Method

Price Guard Wire Method Some form of  Price Guard Wire Method  is generally used to eliminate the errors caused by leakage currents over insulation. Fig. 3.14 illustrates the operation of This Method. In fig 3.14(a), a high resistance mounted on a piece of insulating material is measured by the ammeter voltmeter method. The micro-ammeter measures the sum of the current through the resistor (IR) and the current through the leakage path around the resistor. The measured value of resistance computed from the readings indicated on the voltmeter and the microammeter, will not be a true value but will be in error.   Figure 3.14 Application of  guard  circuit for measurement of high resistance In fig, 3.14 (b), the  guard  terminal has been added to the resistance terminal block. The  guard  terminal surrounds the resistance terminal entirely and is connected to the battery side of the micro-ammeter. The leakage current IL now bypasses t

Negative Booster

Negative booster A negative booster is employed to conform to the regulation that the potential difference between any two points of the rail return shall not exceed 7 V. Two boosters, positive and negative, are used which are mechanically coupled together and driven by a DC motor. The positive booster is connected to the trolley wire (near the generating station) and the negative booster (separately excited) is connected to the track rail.  The 'positive booster' adds voltage to the line while the 'negative booster lowers the potential of the point it is connected to. As we go along the trolley wire away from the generating station/sub-station, the potential drop increases, and the voltage of the trolley wire falls. Since the current returns via the track rail points away from the generating station acquire high potentials. This potential is brought down by the negative boost provided by the negative booster. When the load is sufficiently far away from the generating stati