Magnetic Circuit In Basic Electrical Engineering

Magnetic Circuit

Magnetic circuit shut way to which a magnetic field, spoke to as lines of magnetic motion, is kept. Rather than an electric circuit through which electric charge streams, nothing really streams in a magnetic circuit.

In a ring-molded electromagnet with a little air hole, the magnetic field or motion is altogether bound to the metal center and the air hole, which together shape the magnetic circuit. In an electric engine, the magnetic field is to a great extent restricted to the magnetic post pieces, the rotor, the air holes between the rotor and the shaft pieces, and the metal casing. 

Each magnetic field line makes an entire unbroken circle. Every one of the lines together constitutes the aggregate transition. On the off chance that the transition is separated, with the e goal that piece of it is limited to a segment of the gadget and part to another, the magnetic circuit is called parallel. On the off chance that all the motion is limited to a solitary shut circle, as in a ring-formed electromagnet, the circuit is known as an arrangement magnetic circuit.

In similarity to an electric circuit in which the current, the electromotive power (voltage), and the protection are connected by Ohm's law (current equivalents electromotive power isolated by protection), a comparable connection has been created to portray a magnetic circuit.

The magnetic motion is undifferentiated from the electric current. The magnetomotive power, MMF, is undifferentiated from the electromotive power and might be viewed as the factor that sets up the transition. The MMF is comparable to various turns of wire conveying an electric current and has units of ampere-turns. In the event that either the current through a curl (as in an electromagnet) or the quantity of turns of wire in the loop is expanded, the MMF is more prominent; and if whatever is left of the magnetic circuit continues as before, the magnetic transition increments relatively.

The hesitance of a magnetic circuit is practically equivalent to the protection of an electric circuit. Hesitance relies upon the geometrical and material properties of the circuit that offer resistance to the nearness of the magnetic transition. The hesitance of a given piece of a magnetic circuit is relative to its length and conversely corresponds to its cross-sectional zone and magnetic property of the given material called its penetrability. 

Press, for instance, has an amazingly high penetrability when contrasted with air so it has a nearly little hesitance, or it offers generally little restriction to the nearness of magnetic motion. In an arrangement magnetic circuit, the aggregate hesitance parallels the whole of the individual reluctances experienced around the shut transition way. In a magnetic circuit, in a rundown, the magnetic transition is quantitatively equivalent to the magnetomotive power isolated by hesitance.

Popular posts from this blog

Limitations of Terzaghi Theory

Limitations of Terzaghi Theory The value of the coefficient of consolidation has been assumed to be constant.  The distance d of the drainage path cannot be measured accurately in the field. The thickness of the deposit is generally variable, and an average value has to be estimated.  There is sometimes difficulty 1n locating the drainage face, sometimes thin previous seams that can act as good drainage face are missed in the boring operations. The equation is based on the assumption that the consolidation is one-dimensional. In the field, the consolidation is generally 3-dimensional. The lateral drainage may have a significant effect on the time rate of consolidation. The initial consolidation and secondary consolidation have been neglected. Sometimes these form an important part of the total consolidation. In actual practice, the pressure distribution may be far from linear or uniform. Read More Muller-Breslau principle

Price Guard Wire Method

Price Guard Wire Method Some form of  Price Guard Wire Method  is generally used to eliminate the errors caused by leakage currents over insulation. Fig. 3.14 illustrates the operation of This Method. In fig 3.14(a), a high resistance mounted on a piece of insulating material is measured by the ammeter voltmeter method. The micro-ammeter measures the sum of the current through the resistor (IR) and the current through the leakage path around the resistor. The measured value of resistance computed from the readings indicated on the voltmeter and the microammeter, will not be a true value but will be in error.   Figure 3.14 Application of  guard  circuit for measurement of high resistance In fig, 3.14 (b), the  guard  terminal has been added to the resistance terminal block. The  guard  terminal surrounds the resistance terminal entirely and is connected to the battery side of the micro-ammeter. The leakage current IL now

Negative Booster

Negative booster A negative booster is employed to conform to the regulation that the potential difference between any two points of the rail return shall not exceed 7 V. Two boosters, positive and negative, are used which are mechanically coupled together and driven by a DC motor. The positive booster is connected to the trolley wire (near the generating station) and the negative booster (separately excited) is connected to the track rail.  The 'positive booster' adds voltage to the line while the 'negative booster lowers the potential of the point it is connected to. As we go along the trolley wire away from the generating station/sub-station, the potential drop increases, and the voltage of the trolley wire falls. Since the current returns via the track rail points away from the generating station acquire high potentials. This potential is brought down by the negative boost provided by the negative booster. When the load is sufficiently far aw