Corona - Effect, Formation, Affecting, Disadvantages

Corona Effect Definition: 

The wonder of ionization of encompassing air around the conductor because of which brilliant sparkle with murmuring clamor rises is known as the corona effect. 

Electric power transmission for all intents and purposes manages the mass exchange of electrical vitality, from producing stations arranged numerous kilometers from the principal utilization focuses or the urban communities. Therefore, the long-remove transmission links are of the most extreme need for effective power exchange, which obviously results in tremendous misfortunes over the framework. Limiting those has been a noteworthy test for power designers recently and to do that one ought to have a reasonable comprehension of the sort and nature of misfortunes. The corona effect in power framework has a dominating job in lessening the effectiveness of EHV (additional high voltage lines) which we will focus on, in this article. 

Formation of the corona-

Air is certifiably not an ideal cover, and even under ordinary conditions, the air contains many free electrons and particles. At the point when an electric field power builds up between the channels, these particles and free electrons encounter constrained upon them. Because of this effect, the particles and free electrons get quickened and moved the other way. 

The charged particles amid their movement crash into each other and furthermore with the moderately moving uncharged atoms. Consequently, the quantity of charged particles continues expanding quickly. This expansion the conduction of air between the conductors and a breakdown happens. Subsequently, the curve sets up between the conductors.


Factors affecting corona:

Coming up next are the components influencing the corona; 

1. Effect of supply voltage –

 If the supply voltage is high corona misfortune is higher in the lines. In low-voltage transmission lines, the corona is insignificant, because of the lacking an electric field to look after ionization. 

2. The state of the channel surface – 

If the conduit is smooth, the electric field will be more uniform when contrasted with the harsh surface. The unpleasantness of the conductor is caused by the testimony of earth, dust and by scratching, and so forth. Along these lines, unpleasant line diminishes the corona misfortune in the transmission lines. 

3. Air Density Factor – 

The corona misfortune is conversely relative to the air thickness factor, i.e., corona misfortune, increments with the reduction in the thickness of air. Transmission lines going through a bumpy region may have higher corona misfortune than that comparative transmission lines in the fields in light of the fact that in a sloping zone, the thickness of air is low. 


4. Effect of framework voltage – 

Electric field force in the space around the conduits relies upon the potential contrast between the conveyors. In the event that the potential distinction is high, the electric field force is likewise high, and henceforth corona is additionally high. Corona misfortune, increment with the expansion in the voltage. 

5. The dispersing between conductors – 

If the separation between two conductors is significantly more when contrasted with the distance across the conductor then the corona misfortune happens in the conductor. On the off chance that the separation between them is stretched out past specific restraints, the dielectric medium between them get diminishes and thus the corona misfortune likewise decreases. 

Disadvantages of corona discharge:

The unwanted effects of the corona are: 

  1. The shine shows up over the conductor which demonstrates the power misfortune that happens on it. 

  2. The sound clamor happens on account of the corona effect which causes the power misfortune on the conductor. 

  3. The vibration of the conductor happens as a result of the corona effect. 

  4. The corona effect produces ozone on account of which the conductor ends up destructive. 

  5. The corona effect creates the non-sinusoidal flag accordingly the non-sinusoidal voltage drops happen in the line. 

  6. The corona control misfortune decreases the efficiency of the line. 

  7. The radio and TV impedance happens at stake due to the corona effect. 

Limiting corona: 

Corona diminishes the productivity of transmission lines. In this way, it is important to limit corona. The following variables might be considered to control corona: 

1. Conductor measurement – 

For decreasing corona misfortune, this technique for expanding conductor distances across is extremely effective. Measurements of conductors can be expanded by utilizing empty conductors and by utilizing steel-cored aluminum conductors(ACSR) conductors. 
 

2. The voltage of the line – 

The voltage of transmission lines is settled by monetary contemplations. To expand the problematic voltage the dividing of the conductors is to be expanded, however, this strategy has a few restrictions. 

3. The dispersing between conductors – 

If the space between conductors expands, at that point the voltage drops between them likewise increment because of an expansion in inductive reactance. 

Important points:

  1. Troublesome voltage is the base voltage at which the breakdown of air happens and the corona begins. 

  2. Visual basic voltage is the base voltage at which the obvious corona starts.

Popular posts from this blog

Limitations of Terzaghi Theory

Limitations of Terzaghi Theory The value of the coefficient of consolidation has been assumed to be constant.  The distance d of the drainage path cannot be measured accurately in the field. The thickness of the deposit is generally variable, and an average value has to be estimated.  There is sometimes difficulty 1n locating the drainage face, and sometimes thin previous seams that can act as good drainage faces are missed in the boring operations. The equation is based on the assumption that the consolidation is one-dimensional. In the field, the consolidation is generally 3-dimensional. The lateral drainage may have a significant effect on the time rate of consolidation. The initial consolidation and secondary consolidation have been neglected. Sometimes these form an important part of the total consolidation. In actual practice, the pressure distribution may be far from linear or uniform.

Streamer Theory of Breakdown in Gases

Streamer Theory of Breakdown in Gases According to the Townsend theory firstly, current growth occurs as a result of the ionization process only. But in practice, breakdown voltages were found to depend on the gas pressure and the geometry of the gap. Second chances time lags of the order of 10-5 s, but practically it was observed to occur at a very short time of 10-8 s. Also, the Townsend mechanism predicts a very diffused form of discharge, that actually discharges were found to be filamentary and irregular. Townsend's mechanism failed to explain all these observed phenomena and as a result, The Streamer theory was proposed. The theory predicts the development of a spark discharge directly from a single avalanche in which the space charge developed by the avalanche itself is said to transform the avalanche into a plasma steamer. In Fig 1.7, a single electron starting at the cathode by ionization builds up an avalanche that crosses the gap. The electrons in the a

Price Guard Wire Method

Price Guard Wire Method Some form of  Price Guard Wire Method  is generally used to eliminate the errors caused by leakage currents over insulation. Fig. 3.14 illustrates the operation of This Method. In fig 3.14(a), a high resistance mounted on a piece of insulating material is measured by the ammeter voltmeter method. The micro-ammeter measures the sum of the current through the resistor (IR) and the current through the leakage path around the resistor. The measured value of resistance computed from the readings indicated on the voltmeter and the microammeter, will not be a true value but will be in error.   Figure 3.14 Application of  guard  circuit for measurement of high resistance In fig, 3.14 (b), the  guard  terminal has been added to the resistance terminal block. The  guard  terminal surrounds the resistance terminal entirely and is connected to the battery side of the micro-ammeter. The leakage current IL now